Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Rev Lett ; 132(13): 133201, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38613284

RESUMEN

We implement coherent delocalization as a tool for improving the two primary metrics of atomic clock performance: systematic uncertainty and instability. By decreasing atomic density with coherent delocalization, we suppress cold-collision shifts and two-body losses. Atom loss attributed to Landau-Zener tunneling in the ground lattice band would compromise coherent delocalization at low trap depths for our ^{171}Yb atoms; hence, we implement for the first time delocalization in excited lattice bands. Doing so increases the spatial distribution of atoms trapped in the vertically oriented optical lattice by ∼7 times. At the same time, we observe a reduction of the cold-collision shift by 6.5(8) times, while also making inelastic two-body loss negligible. With these advantages, we measure the trap-light-induced quenching rate and natural lifetime of the ^{3}P_{0} excited state as 5.7(7)×10^{-4} E_{r}^{-1} s^{-1} and 19(2) s, respectively.

2.
Phys Rev Lett ; 129(11): 113202, 2022 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-36154423

RESUMEN

Laser cooling is a key ingredient for quantum control of atomic systems in a variety of settings. In divalent atoms, two-stage Doppler cooling is typically used to bring atoms to the µK regime. Here, we implement a pulsed radial cooling scheme using the ultranarrow ^{1}S_{0}-^{3}P_{0} clock transition in ytterbium to realize subrecoil temperatures, down to tens of nK. Together with sideband cooling along the one-dimensional lattice axis, we efficiently prepare atoms in shallow lattices at an energy of 6 lattice recoils. Under these conditions key limits on lattice clock accuracy and instability are reduced, opening the door to dramatic improvements. Furthermore, tunneling shifts in the shallow lattice do not compromise clock accuracy at the 10^{-19} level.

3.
Nature ; 564(7734): 87-90, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30487601

RESUMEN

The passage of time is tracked by counting oscillations of a frequency reference, such as Earth's revolutions or swings of a pendulum. By referencing atomic transitions, frequency (and thus time) can be measured more precisely than any other physical quantity, with the current generation of optical atomic clocks reporting fractional performance below the 10-17 level1-5. However, the theory of relativity prescribes that the passage of time is not absolute, but is affected by an observer's reference frame. Consequently, clock measurements exhibit sensitivity to relative velocity, acceleration and gravity potential. Here we demonstrate local optical clock measurements that surpass the current ability to account for the gravitational distortion of space-time across the surface of Earth. In two independent ytterbium optical lattice clocks, we demonstrate unprecedented values of three fundamental benchmarks of clock performance. In units of the clock frequency, we report systematic uncertainty of 1.4 × 10-18, measurement instability of 3.2 × 10-19 and reproducibility characterized by ten blinded frequency comparisons, yielding a frequency difference of [-7 ± (5)stat ± (8)sys] × 10-19, where 'stat' and 'sys' indicate statistical and systematic uncertainty, respectively. Although sensitivity to differences in gravity potential could degrade the performance of the clocks as terrestrial standards of time, this same sensitivity can be used as a very sensitive probe of geopotential5-9. Near the surface of Earth, clock comparisons at the 1 × 10-18 level provide a resolution of one centimetre along the direction of gravity, so the performance of these clocks should enable geodesy beyond the state-of-the-art level. These optical clocks could further be used to explore geophysical phenomena10, detect gravitational waves11, test general relativity12 and search for dark matter13-17.

4.
Phys Rev Lett ; 120(18): 183201, 2018 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-29775346

RESUMEN

We demonstrate the absence of a dc Stark shift in an ytterbium optical lattice clock. Stray electric fields are suppressed through the introduction of an in-vacuum Faraday shield. Still, the effectiveness of the shielding must be experimentally assessed. Such diagnostics are accomplished by applying high voltage to six electrodes, which are grounded in normal operation to form part of the Faraday shield. Our measurements place a constraint on the dc Stark shift at the 10^{-20} level, in units of the clock frequency. Moreover, we discuss a potential source of error in strategies to precisely measure or cancel nonzero dc Stark shifts, attributed to field gradients coupled with the finite spatial extent of the lattice-trapped atoms. With this consideration, we find that Faraday shielding, complemented with experimental validation, provides both a practically appealing and effective solution to the problem of dc Stark shifts in optical lattice clocks.

5.
Opt Lett ; 42(7): 1277-1280, 2017 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-28362748

RESUMEN

We demonstrate an easy-to-manufacture 25-mm-long ultra-stable optical reference cavity for transportable photonic microwave generation systems. Employing a rigid holding geometry that is first-order insensitive to the squeezing force and a cavity geometry that improves the thermal noise limit at room temperature, we observe a laser phase noise that is nearly thermal noise limited for three frequency decades (1 Hz to 1 kHz offset) and supports 10 GHz generation with phase noise near -100 dBc/Hz at 1 Hz offset and <-173 dBc/Hz for all offsets >600 Hz. The fractional frequency stability reaches 2×10-15 at 0.1 s of averaging.

6.
Phys Rev Lett ; 119(25): 253001, 2017 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-29303326

RESUMEN

Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an ^{171}Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the 10^{-18} level and beyond.

7.
Phys Rev Lett ; 113(26): 260801, 2014 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-25615296

RESUMEN

The Stark shift due to blackbody radiation (BBR) is the key factor limiting the performance of many atomic frequency standards, with the BBR environment inside the clock apparatus being difficult to characterize at a high level of precision. Here we demonstrate an in-vacuum radiation shield that furnishes a uniform, well-characterized BBR environment for the atoms in an ytterbium optical lattice clock. Operated at room temperature, this shield enables specification of the BBR environment to a corresponding fractional clock uncertainty contribution of 5.5×10(-19). Combined with uncertainty in the atomic response, the total uncertainty of the BBR Stark shift is now 1×10(-18). Further operation of the shield at elevated temperatures enables a direct measure of the BBR shift temperature dependence and demonstrates consistency between our evaluated BBR environment and the expected atomic response.

8.
Science ; 341(6151): 1215-8, 2013 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-23970562

RESUMEN

Atomic clocks have been instrumental in science and technology, leading to innovations such as global positioning, advanced communications, and tests of fundamental constant variation. Timekeeping precision at 1 part in 10(18) enables new timing applications in relativistic geodesy, enhanced Earth- and space-based navigation and telescopy, and new tests of physics beyond the standard model. Here, we describe the development and operation of two optical lattice clocks, both using spin-polarized, ultracold atomic ytterbium. A measurement comparing these systems demonstrates an unprecedented atomic clock instability of 1.6 × 10(-18) after only 7 hours of averaging.

9.
Phys Rev Lett ; 108(15): 153002, 2012 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-22587248

RESUMEN

Presently, the Stark effect contributes the largest source of uncertainty in a ytterbium optical atomic clock through blackbody radiation. By employing an ultracold, trapped atomic ensemble and high stability optical clock, we characterize the quadratic Stark effect with unprecedented precision. We report the ytterbium optical clock's sensitivity to electric fields (such as blackbody radiation) as the differential static polarizability of the ground and excited clock levels α(clock) = 36.2612(7) kHz (kV/cm)(-2). The clock's uncertainty due to room temperature blackbody radiation is reduced by an order of magnitude to 3×10(-17).

10.
Phys Rev Lett ; 107(10): 103902, 2011 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-21981504

RESUMEN

We study ultracold collisions in fermionic ytterbium by precisely measuring the energy shifts they impart on the atoms' internal clock states. Exploiting Fermi statistics, we uncover p-wave collisions, in both weakly and strongly interacting regimes. With the higher density afforded by two-dimensional lattice confinement, we demonstrate that strong interactions can lead to a novel suppression of this collision shift. In addition to reducing the systematic errors of lattice clocks, this work has application to quantum information and quantum simulation with alkaline-earth atoms.

11.
Phys Rev Lett ; 103(6): 063001, 2009 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-19792559

RESUMEN

We experimentally investigate an optical clock based on ;{171}Yb (I = 1/2) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of 3.4 x 10;{-16}, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock transition frequency relative to the NIST-F1 Cs fountain clock and find the frequency to be 518 295 836 590 865.2(0.7) Hz.

12.
Science ; 324(5925): 360-3, 2009 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-19372424

RESUMEN

At ultracold temperatures, the Pauli exclusion principle suppresses collisions between identical fermions. This has motivated the development of atomic clocks with fermionic isotopes. However, by probing an optical clock transition with thousands of lattice-confined, ultracold fermionic strontium atoms, we observed density-dependent collisional frequency shifts. These collision effects were measured systematically and are supported by a theoretical description attributing them to inhomogeneities in the probe excitation process that render the atoms distinguishable. This work also yields insights for zeroing the clock density shift.

13.
Phys Rev Lett ; 100(14): 140801, 2008 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-18518019

RESUMEN

The 1S0-3P0 clock transition frequency nuSr in neutral 87Sr has been measured relative to the Cs standard by three independent laboratories in Boulder, Paris, and Tokyo over the last three years. The agreement on the 1 x 10(-15) level makes nuSr the best agreed-upon optical atomic frequency. We combine periodic variations in the 87Sr clock frequency with 199Hg+ and H-maser data to test local position invariance by obtaining the strongest limits to date on gravitational-coupling coefficients for the fine-structure constant alpha, electron-proton mass ratio mu, and light quark mass. Furthermore, after 199Hg+, 171Yb+, and H, we add 87Sr as the fourth optical atomic clock species to enhance constraints on yearly drifts of alpha and mu.

14.
Science ; 319(5871): 1805-8, 2008 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-18276849

RESUMEN

Optical atomic clocks promise timekeeping at the highest precision and accuracy, owing to their high operating frequencies. Rigorous evaluations of these clocks require direct comparisons between them. We have realized a high-performance remote comparison of optical clocks over kilometer-scale urban distances, a key step for development, dissemination, and application of these optical standards. Through this remote comparison and a proper design of lattice-confined neutral atoms for clock operation, we evaluate the uncertainty of a strontium (Sr) optical lattice clock at the 1 x 10(-16) fractional level, surpassing the current best evaluations of cesium (Cs) primary standards. We also report on the observation of density-dependent effects in the spin-polarized fermionic sample and discuss the current limiting effect of blackbody radiation-induced frequency shifts.

15.
Opt Lett ; 32(6): 641-3, 2007 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-17308587

RESUMEN

We demonstrate phase and frequency stabilization of a diode laser at the thermal noise limit of a passive optical cavity. The system is compact and exploits a cavity design that reduces vibration sensitivity. The subhertz laser is characterized by comparison with a second independent system with similar fractional frequency stability (1x10(-15) at 1 s). The laser is further characterized by resolving a 2 Hz wide, ultranarrow optical clock transition in ultracold strontium.

16.
Phys Rev Lett ; 96(20): 203201, 2006 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-16803171

RESUMEN

With ultracold 88Sr in a 1D magic wavelength optical lattice, we performed narrow-line photoassociation spectroscopy near the 1S0 - 3P1 intercombination transition. Nine least-bound vibrational molecular levels associated with the long-range 0u and 1u potential energy surfaces were measured and identified. A simple theoretical model accurately describes the level positions and treats the effects of the lattice confinement on the line shapes. The measured resonance strengths show that optical tuning of the ground state scattering length should be possible without significant atom loss.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...